Belt scale

Specifications:  Exc+(Red); Exc-(Black); Sig+(Green);Sig-(White)   


Product Detail

Product Tags

Application

Belt scale

Specifications:  Exc+(Red); Exc-(Black); Sig+(Green);Sig-(White)   

Item

Unit

Parameter

Accuracy class to OIML R60

C2

Maximum capacity(Emax)

lb

100、150、200、250

Minimum LC verification interval(Vmin)

% of Emax

0.0200

Sensitivity(Cn)/Zero balance

mV/V

3.0±0.005/0±0.03

Temperature effect on zero balance (TKo)

% of Cn/10K

±0.02

Temperature effect on sensitivity(TKc)

% of Cn/10K

±0.02

Hysteresis error(dhy)

% of Cn

±0.0300

Non-linearity(dlin)

% of Cn

±0.0250

Creep(dcr) over 30 min

% of Cn

±0.020

Input (RLC) & Output resistance(R0)

Ω

400±10 & 352±3

Nominal range of excitation voltage(Bu)

V

5~12

Insulation resistance (Ris) at50Vdc

≥5000

Service temperature range(Btu)

-30...+70

Safe load limit(EL) & Breaking load(Ed)

% of Emax

120 & 200

Protection class according to EN 60 529 (IEC 529)

IP66

Material:Measuring element

Cable sheath

Stainless or alloy steel

PVC

Maximum capacity(Emax)

lb

100

150

200

250

Deflection at Emax(snom),approx

mm

<0.5

Weight(G),approx

kg

0.15

0.18

Cable:Diameter:Φ4mm  length

m

1.5

Advantage

1. Years of R&D, production and sales experience, advanced and maturity technology.

2. High precision, durability, interchangeable with sensors produced by many famous brands, competitive price, and high-cost performance.

3. Excellent engineer team, customize different sensors and solutions for different needs.

Why choose us

YantaiJiaijia Instrument Co., Ltd. is an enterprise that emphasizes development and quality. With stable and reliable product quality and good business reputation, we have won the trust of our customers, and we have followed the market development trend and continuously developed new products to meet the needs of our customers. All products have passed internal quality standards.


  • Previous:
  • Next:

  • Write your message here and send it to us